Original catalogue drawing - NSK catalogue, page 147
Scanned from the manufacturer catalogue page listing this part number. All part numbers printed on that table share the same drawing.
Scale cross-section
Blue = inner / outer ring, yellow = rolling element. Drawn to scale from this part's own
dimensions for selection reference only - not a manufacturing or assembly drawing.
Dimension table (mm / inch)
Symbol
Dimension
mm
inch
d
Bore diameter
120
4.7244
D
Outside diameter
250
9.8425
T
Overall assembly width
102
4.0157
Notes
Thrust bearing ratings are axial values Ca / Coa; T is the overall height. Weights are given in kg. Load ratings are shown in both the original catalogue units and the converted value (1 N = 0.2248 lbf). Data is provided for selection reference only - confirm against the latest official catalogue before ordering.
Main dimensions
Bore d (mm)
120
Bore d (in)
4.7244
Outside dia. D (mm)
250
Outside dia. D (in)
9.8425
Overall width T (mm)
102
Overall width T (in)
4.0157
Load ratings & speeds
Basic dynamic axial rating Ca (lbs)
108000
Basic static axial rating Coa (lbs)
313000
Limiting speed - grease (rpm)
6,000
Limiting speed - oil (rpm)
900
Weight
Weight (kg)
26.199
Mounting dimensions (fillets / shoulders)
Chamfer r (in)
0.118
Shaft shoulder da min (in)
7.722
Housing shoulder Da (in)
6.856
Bearing life (ISO 281 basic rating life)
C / P
Equivalent load P (N)
L10 (106 rev)
L10h at 2,000 rpm
4
120,102
102
847
6
80,068
392
3,271
8
60,051
1,024
8,533
10
48,041
2,154
17,954
15
32,027
8,323
69,362
Basic rating life per ISO 281: L10 = (C/P)10/3 with C = 480,408 N. Hours = L10 x 106 / (60n). Life-modification factors for lubrication, contamination and temperature (aISO) are not included.
Source & traceability
Brand
NSK
Source catalogue
NSK inch product catalogue
Catalogue page
p.149 (dimensions) / p.150 (ratings)
Dimensions in inches and millimetres, load ratings in lbs.
Send us the quantity you need and we will come back with price and
lead time, normally within 24 hours. Equivalent parts from other brands can be quoted at the same time.